๐Ÿšฟ Plumbing ยท 6 min read

Vent Pipe Sizing โ€” Individual, Branch, and Stack Vents

The vent system does one job โ€” keep air behind the water so traps do not siphon. Undersized or overlong vents pull trap seals and let sewer gas into the building.

Why vents exist

As waste falls down a stack it drags air with it, creating suction behind it. Without a vent path, that suction pulls water out of nearby fixture traps. Vents admit make-up air so the trap seal holds.

Advertisement

Size by drain served and length

A vent is sized from the DFU load of the drain it protects and the developed length from the vent connection to the point it reaches outside air (or joins a vent stack).

Drain servedDFUVent size (short runs)
32โ€“40 mm branch≤ 832 mm
50 mm branch≤ 2440 mm
75 mm branch≤ 4250 mm
100 mm stack≤ 50050โ€“75 mm

Long developed lengths force the next size up โ€” the tables cut the allowable length roughly in half for each size step down.

The key rules

Common configurations

Individual vent โ€” one fixture. Common vent โ€” two fixtures on the same or adjacent levels. Wet vent โ€” a drain that also carries vent air for limited fixtures. Circuit vent โ€” one vent for a battery of up to eight floor-mounted fixtures.